Search results for "Ocular surgery"

showing 4 items of 4 documents

Distribution of Anterior Chamber Angle Width and Correlation With Age, Refraction, and Anterior Chamber Depth—The Gutenberg Health Study

2016

PURPOSE Scheimpflug imaging allows quantitative analysis of the width of the anterior chamber angle. We report the population-based distribution of the anterior chamber angle width using this noncontact imaging technique and investigate associated factors. METHODS A population-based cross-sectional study was carried out in Germany. A comprehensive ophthalmologic examination including refraction, biometry, and Scheimpflug imaging was performed. Automated measurement of the anterior chamber angle was performed in each anterior chamber quadrant. Exclusion criteria were previous ocular surgery or inadequate image quality. Association analyses were carried out to determine independently associat…

AdultMaleAnterior ChamberOcular surgeryScheimpflug principlePopulationGlaucoma610 Medicine & healthDiagnostic Techniques OphthalmologicalRefraction OcularAnterior chamber angleCornea03 medical and health sciences0302 clinical medicineRisk FactorsGermanyLens CrystallinemedicineHumans610 Medicine & healtheducationAgedSex Characteristicseducation.field_of_studybusiness.industryAge FactorsAstigmatismMiddle Agedmedicine.diseaseRefractionCross-Sectional StudiesOphthalmologic examination030221 ophthalmology & optometryFemaleGlaucoma Angle-ClosureNuclear medicinebusiness030217 neurology & neurosurgeryShallow anterior chamberInvestigative Opthalmology & Visual Science
researchProduct

Agreement of white-to-white measurements with the IOLMaster 700, Atlas 9000, and Sirius systems

2018

Current advances in ocular surgery require the evaluation of differences in automated white-to-white (WTW) measurements between systems. We aim to analyze three different commonly used devices in clinical practice: the IOLMaster 700, the Atlas 9000, and the Sirius.Ninety right eyes of ninety healthy subjects were included. Measurements of WTW distances were taken with each device for all subjects in the same session and by the same observer. Statistical comparison was carried out by means of the rANOVA procedure and the Bonferroni post-hoc test. In addition, the Bland-Altman analysis was applied in order to perform pairwise comparisons.Average WTW values obtained by the IOLMaster 700, the A…

AdultMaleWhite to whitebusiness.industryOcular surgerySiriusBiomedical EngineeringOphthalmologic Surgical ProceduresGeneral MedicineMiddle AgedYoung Adult03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureAtlas (anatomy)030221 ophthalmology & optometrymedicineHumansOptometryFemaleSurgerybusiness030217 neurology & neurosurgeryOphthalmologic Surgical ProcedureDemographyExpert Review of Medical Devices
researchProduct

Aseptic Production vs. Terminal Sterilization

2000

The safety of substance use in intraocular surgery ideally requires the absence of all biologically-active components capable of causing an inflammatory reaction. Substance purity is achieved with isolation and cleansing methods (e.g., of the polysaccharide), which remove any biological component with infective potential. The methods of production for polysaccharide isolation should remove biological agents, regardless of its origin. Hyaluronic acid is isolated either from rooster combs or biological fermentation. Use of this substance showed the development of postoperative intraocular inflammatory reactions resulting from contaminations from both sources. OVD should have low endotoxin val…

Methods of productionSterilization processSterilityChemistryTerminal SterilizationAseptic processingIntraocular surgeryFood scienceSubstance useSterility assurance level
researchProduct

ATD perimetry in glaucoma and ocular hypertensive patients. A preliminar study

2007

Purpose: The new ATD perimetry assesses contrast sentivity thresholds for the three afferent sensory pathways of the visual system. Our aim is to compare contrast sensitivity to stimuli with different spatio-temporal frequencies in glaucomatous (G) and ocular hypertensive (OHT) subjects. Methods: Twenty three G and OHT subjects were selected from the ophthalmic clinic, all subjects signed an informed consent. Inclusion criteria were diagnosis of G or OHT, normal Farnsworth-Munsell color test, ametropia less than 6 D, visual acuity over 20/30, absence of previous ocular surgery and experience in perimetry. Twenty locations and the fovea were evaluated in a 60o x 40o fovea-centered field. Eig…

medicine.medical_specialtyVisual acuitybusiness.industryOcular surgeryColor testGlaucomamedicine.diseaseOphthalmologyAfferentOphthalmologymedicineStatistical analysisAnalysis of variancemedicine.symptomHigh intraocular pressurebusinessActa Ophthalmologica Scandinavica
researchProduct